fifotrack Fuel sensor settings in Uffizio Platform
- fifotrack Team
- May 24
- 1 min read
Updated: 16 hours ago
This example is based on fifotrack S20 model.
All S/A series vehicle GPS tracker models' AD1 are the same way.
Analog input 1 (AD1) connected with AS10 capacitive fuel sensor
Fuel tank type: regular size shape (irregular size fuel tank is another way)
Full fuel capacity: 75 liters
Step 1: Find the object, double click, click "sensors" and configure


Connection Type: AD input1
Connected Sensor: Fuel Level
Click "Calibration" for next step
Step 2: Fill the Calibrtion menu
Sensor output unit: choose "voltage"
Conversion factor: always is "1"
Tank Capacity: fill the actual fuel tank full capacity, unit is liter. In this case is 75 liters
Below three lines are always same constant value
Empty Tank Reading: 0
Half Tank Reading: 2.048
Full Tank Reading: 4.096

Background knowledge: the fuel sensor's output voltage is 0-5V, but the GPS tracker device converts the voltage 0-5V to 0-4096 and uploads it to the platform. Uffizio treat this 0-4096 AD value as direct voltage 0-4.096V
After settings check the result

.........................................................................................................................................................................
If the fuel tank is irregular size, the fuel level height and the fuel capacity is not linear relationship.
Calibration is needed.
In Uffizio (Trakzee) platform, you can uplaod the calibration file by selecting "Manual" option.

Below is the calibraiton file example:
Full capacity is 135 liters

Comments